COMPANY PRODUCT

530 Coating Thickness Gauge

Product description:

1.Measurement Range: 01250um or 050mil 2. Accuracy: [(1%~3%)H+1um] Note:H is thickness reading 3. powers down after 60 seconds of no activity. 530 canmeasurethethicknessofnon-magneticcoatinglayerscove
  • TIME®2510 Ferrous and Non-ferrous Coating Thickness Gauge
  • TIME®2501Digital Coating Thickness Gauge
  • TIME2500 Coating Thickness Meter
  • 560Coating Thickness Gauge

Share With:

We"re here to help:
Easy ways to get the answers you need.
Send E-mailChat Now
1.Measurement Range:   0—1250um or 0—50mil
2. Accuracy:± [(1%~3%)H+1um]  Note:H is thickness reading
3. powers down after 60 seconds of no activity.

530  can measure the thickness of non-magnetic coating layers covered on magnetic substrate. Such as: non-magnetic (aluminum, chrome, copper, enamel, rubber, paint) covered on magnetic substrate (steel, iron, alloy and magnetic stainless steel)

1、Power-on
Keystroke once;Wait until  READY! is displayed on the LCD. Now the gauge is ready for measurements.
2、Zeroing
Keystroke twice; when  BASE ZERO  is displayed, place flat on surface; hold steady. After measurement is obtained,  DONE  is shown and gauge beeps. Then lift gauge.
Note: Please conduct zeroing process after changing base. Zeroing process could be repeated for better results.
3、Two-Point User Calibration
Keystroke three times, enter into the process of tow-point user calibration; when
 USER CAL BASE  is shown on the LCD, please conduct a measurement on the base first; when
 S1  is shown on the LCD, place Shim S1 on the base, conduct a measurement on shim S1 and lift gauge; when
 S2  is shown on the LCD, place Shim S2 on the base, conduct a measurement on shim S2 and lift gauge; When  DONE  is displayed, it is ready for use.
Note: The two-point user calibration process could be repeated for better results.
4、Unit Change
Keystroke four times, convert from ums to mils or vice versa.
5、Reset
Keystroke five times, gauge resets.


admin@hssdtest.com

+86-15910081986