COMPANY PRODUCT

6100 Ultrasonic Flaw Detector

Product description:

Overview This is a portable industrial non-destructive flaw detector, which can rapidly, easily and accurately inspect,locate, evaluate and diagnose various defects (crack, inclusion and pinhole, etc.
  • HUT1130  Ultrasonic Flaw Detector
  • 6500 Ultrasonic Flaw Detector
  • 5100 Ultrasonic Flaw Detector

Share With:

We"re here to help:
Easy ways to get the answers you need.
Send E-mailChat Now
Overview
 
This is a portable industrial non-destructive flaw detector, which can rapidly, easily and accurately inspect,locate, evaluate and diagnose various defects (crack, inclusion and pinhole, etc.) in a workpiece without destruction.It can be used both in a lab and field. The instrument can be widely used in any fields that need defect inspection and quality controlling e.g. manufacturing industry, iron & steel metallurgical industry, metalworking, chemical industry, etc., also be broadly used in the active safety inspection and service-life evaluation in such fields as aerospace, railway transportation and boiler pressure vessels, etc. It is an essential instrument for non-destructive inspection industry.
 
When the ultrasonic wave propagates in a job, one can detect the defect in it by the influence on the propagation of ultrasonic wave based on the acoustic characteristic demonstrated by the defect in the material. Based on this principle, by using ultrasonic wave one can measure such defects as crack, pinhole and inclusion in such media as metal, non metal and composite, etc.
 
Measuring Range and Measuring Error
Range of scanning: 0 mm ~10000 mm
Resolution for scanning: 0.1mm (2.5mm ~100mm)
1mm (100 mm ~5000mm)
Range of gain: 0dB ~120 dB
D-Delay: -20μs~+3400μs
P-Delay: 0μs~99.99μs
Sound speed : 1000 m/s~15000m/s
Operation Environment
Temperature: -10℃~50℃
Humidity: 20%~90%RH
Free of strong magnetic field and corrosion.
Power supply
Li battery 7.4V 4800mAh
Overall Dimension and Weight
Overall dimension: 240mm×150mm×50mm
Weight: 1.6kg
Performance Features
l  Automated calibration of transducer Zero Offset and/or Velocity ;
l  Automated gain、Peak Hold and Peak Memory;
l  Automated display precise flaw location(Depth d、level p、distance s、amplitude、sz dB、ф);
l  Automated switch three staff gauge ((Depth d、level p、distance s);
l  100 independence setup, any criterion can be input freely, we can work in the scene without test block
l  Big memory of 300 A graph.
l  Gate and DAC alarm;Acoustic-Optical alarm;
l  RS232/USB port,communication with pc is easy;
l  The embeded software can be online updated;
l  Li battery, continue working time up to 10 hours;
l  Display freeze;
l  Automated echo degree;
l  Angles and K-value;
l  Lock and unlock function of system parameters;
l  Dormancy and screen savers;
l  Electronic clock calendar ;
l  Two gates setting and alarm indication;
l  High-speed capture and very low noise;
l  DACAVGB Scan ; Solid metal housing ;
l  Automated calculate the size of the flaw with w ide bottom type in AVG function.
l  AWS D1.1
l  6dB DAC functions;
l  Automated make video of test process and play;
l  Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to
read from all angles;
l  Powerful pc software and reports can be export to excel;
 
Technical Parameters
 
Designation Technical Data
Range of scanning (mm) Range of scanning (mm):0~10000
Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350,400,450,500,600,700,800,900,1000,2000,3000,4000,5000,6000,7000,8000,10000
Adjusting step: 0.1mm(2.5 mm~99.9mm),1mm(100mm~10000mm)
D-delay (ms) D-delay (ms):-20~+3400
Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600,
700,800,900,1000,1500,2000,2500,3000,3400.
Adjusting steps: 0.1(-20ms~999.9ms),1(1000ms~3400ms)
P-delay (ms) P-delay:0.0~99.99
Adjusting steps: 0.01
MTLVEL(m/s) MTLVEL:1000~15000
7 fixed levels: 2260,2730,3080,3230,4700,5920,6300,12000
Adjusting steps:  1
Working mode Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission  (transmission probe)
Frequency Range (MHz) 0.5~15
Gain adjustment (dB) 0~120
Adjusting step: 0.0,0.1,0.5,1,2,6,12
Reject 0%~80% of screen height, step: 1%
Vertical linear error Vertical linear error is not more than 3%
Horizontal linear error Not more than 0.2% in the scanning range
Sensitivity Leavings ≥62 dB
Dynamic range ≥34dB
Alarm Three modes, i.e. forbidden wave, loss wave and auto
A-Scan display area Full screen or local
A-Scan display freezing and de-freezing  A-Scan filling
Data save 300 A-Scan images (including setting of instrument)
 
Standard communication interface with PC RS232/USB
Measuring unit mm/inch
Battery Li battery 7.4V  4800mAh
Power adaptor Input 100V~240V/50Hz~60Hz
Output 9VDC/1.5A
Working temperature -10℃~50℃
Working humidity 20%~90%
Port type BNC / LEMO
Overall dimension (mm) 240×150×50
Weight (kg) 1.6
 
 
Standard Configurations and Options
 
Standard Configuration
Table 1.1 List of standard configurations
Designation Quantity
Main unit 1
1.5A/9V power adaptor 1
probe connecting cable 2
Carrying case 1
Instruction manual 1
Straight probe 10mm 4MHz (One)
Angle probe 8×9 60°4MHz (One)
        
Options
Table 1.2 List of options
Designation Quantity
Serial cable 1 (9 pin)
Communication software for PC 1 set



admin@hssdtest.com